Citrix netscaler sdx-14000 40g

The NetScaler SDX 14020–40G, SDX 14040–40G, SDX 14060–40G, SDX 14080–40G, and SDX 14100–40G are 2U appliances. Each model has two 6-core…

sunol tech · 2025-03-24 02:35 · 0 claps · 2.1 min read
#citrix #netscaler #sdx14000 #40g #appliances
Open on Medium ↗

Citrix netscaler sdx-14000 40g

The NetScaler SDX 14020–40G, SDX 14040–40G, SDX 14060–40G, SDX 14080–40G, and SDX 14100–40G are 2U appliances. Each model has two 6-core processors and 64 GB of memory. The SDX 14020–40G/14040–40G/14060–40G/14080–40G/14100–40G appliances are available in the four-40G QSFP+ ports and sixteen 10G SFP+ ports (4x40G QSFP+ + 16x10G SFP+) configuration.

For information on the software releases supported on the NetScaler hardware platforms, see NetScaler SDX hardware-software compatibility matrix.

The NetScaler MPX 14020/14030/14040/14060/14080/14100 are 2U appliances. Each model has two 6-core processors and 64 GB of memory and sixteen 10G SFP+ ports (16x10G SFP+).

For information about the software releases supported on the NetScaler hardware platforms, see NetScaler hardware software support matrix.

The following figure shows the front panel of the MPX 14020/14030/14040/14060/14080 (16x10G SFP+) appliance.

The NetScaler MPX 14020/14030/14040/14060/14080/14100 appliances have the following ports:

  • RS232 serial Console Port.
  • 10/100Base-T copper Ethernet Port (RJ45), also called the LOM port. You can use this port to remotely monitor and manage the appliance independently of the NetScaler software.
  • Two 10/100/1000Base-T copper Ethernet Management Ports (RJ45), numbered 0/1and 0/2 from left to right. These ports are used to connect directly to the appliance for system administration functions.
  • Network Ports, sixteen 10G SFP+ ports (16x10G SFP+).

The following components are visible on the back panel of the MPX 14020/14030/14040/14060/14080/14100 appliance:

  • Two 240 GB or larger removable solid-state drives in a redundant array of independent disks (RAID) configuration. In a RAID configuration, the same data is stored on multiple drives to improve performance, increase storage capacity, lower the risk of data loss, and provide fault tolerance. The two SSDs store the same data. If one fails and you replace it, the new SSD mirrors the other one.
  • Note: Drive densities might increase as components become EOL but its size is never smaller than the original.
  • Power switch, which turns power to the appliance on or off. Press the switch for less than two seconds to shut off the power.
  • Two power supplies, each rated at 1000 watts, 100–240 volts. Each power supply has an LED that indicates the status of the power supply, as described in Common hardware components.


메타데이터
post_id
f6e5d87f14a5
slug
citrix-netscaler-sdx-14000-40g-f6e5d87f14a5
url
https://medium.com/@sunoltech/citrix-netscaler-sdx-14000-40g-f6e5d87f14a5
canonical_url
https://medium.com/@sunoltech/citrix-netscaler-sdx-14000-40g-f6e5d87f14a5
author_url
https://medium.com/@sunoltech
status
ok
fetched_at
2026-07-20 13:40:40